Supported hardware |
|
|
|
| |
|
The
following tables list all hardware devices that can be used with our
software. It will give you an overview of the device functions and the
sample rate that is available with the software. Values are not
garanteed but good for orientation.
| |
|
|
|
|
|
|
|
|
|
|
| |
|
| |
Explanations
| |
|
|
| |
|
DI |
Number of digital input channels |
Anzahl digitaler Eingangskan�le |
DO |
Number of digital output channels |
Anzahl digitaler Ausgangskan�le |
PIO |
Number of digital IO with programmable direction |
Anzahl Eing�nge/Ausg�nge mit programmierbarer Richtung |
AD |
Number of analogue input channels |
Anzahl analoger Eing�nge |
DA |
Number of analogue outut channels |
Anzahl analoger Ausg�nge |
REL |
Number of relay outputs |
Anzahl der Relaisaug�nge |
CNT |
Number of hardware counters |
Anzahl der Hardwarez�hler |
ProfiLab |
Samples per second with ProfiLab |
Abtastungen pro Sekunde mit ProfiLab |
RealView |
RealView sample interval |
RealView-Abtastintervall |
SIM |
Maximum sample rate with ProfiLab simulation frequency |
Maximale Abtastung mit ProfiLab-Simulationsfrequenz |
NA |
Device supported with unknown sanple rate |
Ger�t kann mit unbekannter Abtastrate genutzt werden |
- |
Not available or not supported |
Nicht vorhanden oder nicht unterst�tzt | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| |
Internal cards |
|
|
|
| |
| |
Channels |
|
Sample rate
| |
|
| | |
|
|
DI |
DO |
PIO |
AD |
DA |
REL |
CNT |
Digital-ProfiLab |
DMM-ProfiLab |
ProfiLab-Expert |
RealView |
IO-Cards with 8255 port |
- |
- |
24 |
- |
- |
- |
- |
SIM |
- |
SIM |
- |
IO-Cards with 8255 port |
16 |
16 |
- |
- |
- |
- |
3 |
- |
- |
SIM |
- |
Meilhaus ME-8100 B |
32 |
32 |
- |
- |
- |
- |
3 |
- |
- |
SIM |
- |
Meilhaus ME-4680 |
- |
- |
32 |
32 |
4 |
- |
3 |
- |
- |
10 |
100 ms |
Meilhaus ME-4670 |
- |
- |
32 |
32 |
4 |
- |
3 |
- |
- |
10 |
100 ms |
Meilhaus ME-4660 |
- |
- |
32 |
16 |
2 |
- |
3 |
- |
- |
20 |
50 ms |
Meilhaus ME-4650 |
- |
- |
32 |
16 |
- |
- |
- |
- |
- |
20 |
50 ms |
Meilhaus ME-1400 /D |
- |
- |
24 |
- |
- |
- |
15 |
- |
- |
150 |
- |
Meilhaus ME-1400 /C |
- |
- |
24 |
- |
- |
- |
15 |
- |
- |
150 |
- |
Meilhaus ME-1400 B/EB |
- |
- |
48 |
- |
- |
- |
6 |
- |
- |
150 |
- |
Meilhaus ME-1400 A/EA |
- |
- |
24 |
- |
- |
- |
3 |
- |
- |
150 |
- |
Meilhaus ME-1400 /E |
- |
- |
24 |
- |
- |
- |
- |
- |
- |
150 |
- |
Meilhaus ME-630 |
16 |
- |
- |
- |
- |
16 |
- |
- |
- |
200 |
- |
Meilhaus ME-96 |
10 |
8 |
- |
- |
- |
- |
- |
- |
- |
100 |
- |
Meilhaus ME-95 |
- |
16 |
- |
- |
- |
- |
- |
- |
- |
100 |
- |
Meihaus ME-94 |
18 |
- |
- |
- |
- |
- |
- |
- |
- |
100 |
- |
BMC PC16TR |
- |
- |
16 |
16 |
- |
- |
- |
- |
- |
NA |
NA |
BMC PC20TR |
- |
- |
32 |
16 |
2 |
- |
- |
- |
- |
NA |
NA |
Kolter PCI Counter-1 |
- |
3 |
- |
- |
- |
- |
3 |
- |
- |
SIM |
- |
Kolter PCI DAC 416 |
- |
2 |
- |
- |
4 |
- |
- |
- |
- |
NA |
- |
Kolter PCI ADGVT |
- |
- |
- |
16 |
- |
- |
- |
- |
- |
50 |
20 ms |
Kolter PCI AD12(16) DAC4 |
1 |
- |
- |
16 |
4 |
- |
- |
- |
- |
50 |
20 ms |
Kolter PCI AD12(16) LC |
1 |
- |
- |
16 |
- |
- |
- |
- |
- |
50 |
20 ms |
Kolter PCI 16 In/Out Opto |
16 |
16 |
- |
- |
- |
- |
- |
- |
- |
SIM |
- |
Kolter PCI 16 In/Out TTL |
16 |
16 |
- |
- |
- |
- |
- |
- |
- |
SIM |
- |
Kolter PCI 16 Rel./16 Opto |
16 |
- |
- |
- |
- |
16 |
- |
- |
- |
SIM |
- |
Kolter PCI 16 Rel. |
- |
- |
- |
- |
- |
16 |
- |
- |
- |
SIM |
- |
Kolter PCI 8 Rel. |
- |
- |
- |
- |
- |
8 |
- |
- |
- |
SIM |
- |
Kolter AD12LC (ISA) |
- |
- |
8 |
16 |
- |
- |
- |
- |
- |
NA |
NA |
Kolter ADGVT 12/16 (ISA) |
- |
- |
- |
12 |
- |
- |
- |
- |
- |
NA |
NA |
Kolter DAC 4 (ISA) |
- |
- |
- |
- |
4 |
- |
- |
- |
- |
NA |
- |
Kolter Opto 3 (ISA) |
16 |
16 |
- |
- |
- |
- |
- |
- |
- |
SIM |
- |
ELV ADA 16-2 (ISA) |
- |
- |
- |
8 |
8 |
- |
- |
- |
- |
NA |
NA |
ELV ADA 8 (ISA) |
- |
- |
- |
8 |
8 |
- |
- |
- |
- |
NA |
NA |
ELV PIO 32 (ISA) |
32 |
32 |
- |
- |
- |
- |
- |
SIM |
- |
SIM |
- | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| |
External devices on LPT port
| |
|
|
| |
| |
Channels |
|
Sample rate
| |
|
| | |
|
|
DI |
DO |
PIO |
AD |
DA |
REL |
CNT |
Digital-ProfiLab |
DMM-ProfiLab |
ProfiLab-Expert |
RealView |
ELV Analyzer |
12 |
12 |
- |
- |
- |
- |
- |
60 |
- |
60 |
- |
ELV CSI 7001 |
8 |
- |
- |
- |
- |
8 |
- |
1 |
- |
1 |
- |
HygroTec watchdog relay card |
4 |
- |
- |
- |
- |
8 |
- |
- |
- |
1 |
- |
HygroTec relay card |
- |
- |
- |
- |
- |
- |
- |
1 |
1 |
1 |
- |
LPT port access |
5 |
11 |
- |
- |
- |
- |
- |
SIM |
SIM |
SIM |
- | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| |
External devices on COM port
| |
|
|
| |
| |
Channels |
|
Sample rate
| |
|
| | |
|
|
DI |
DO |
PIO |
AD |
DA |
REL |
CNT |
Digital-ProfiLab |
DMM-ProfiLab |
ProfiLab-Expert |
RealView |
BMC relay card |
- |
- |
- |
- |
- |
8 |
- |
1 |
1 |
1 |
- |
Conrad 8-Kanal-Messmodul |
- |
- |
- |
8 |
- |
- |
- |
- |
- |
6 |
200 ms |
ELV CSI 7002 |
8 |
- |
- |
- |
- |
8 |
- |
NA |
- |
NA |
- |
ELV ADS 12 |
- |
- |
- |
8 |
- |
- |
- |
- |
- |
30 |
20 ms |
ELV M232 |
8 |
8 |
- |
6 |
- |
- |
- |
- |
- |
1 |
2 sec. |
ELV IO88 |
8 |
8 |
- |
- |
- |
- |
- |
20 |
- |
20 |
- |
ELV PC-I/O 16 |
16 |
16 |
- |
- |
- |
- |
- |
60 |
- |
60 |
- |
ModulBus SIOS |
8 |
8 |
- |
4 |
2 |
- |
- |
50 |
- |
50 |
100 ms |
ModulBus CompuLab |
8 |
8 |
- |
2 |
- |
- |
- |
80 |
- |
80 |
50 ms |
ModulBus SERAI 1-8 |
- |
- |
- |
1 |
- |
- |
- |
- |
- |
200 |
5 ms |
ModulBus SERAI 6-10 |
- |
- |
- |
6 |
- |
- |
- |
- |
- |
20 |
10 ms |
ModulBus SERAI 8-12 |
- |
- |
- |
8 |
- |
- |
- |
- |
- |
30 |
50 ms |
Kolter VModul I/O |
16 |
16 |
- |
- |
- |
- |
- |
- |
- |
NA |
- |
Kolter VModul A/D |
- |
- |
- |
16 |
- |
- |
- |
- |
- |
1 |
1 sec. |
Velleman K8056 |
- |
- |
- |
- |
- |
8 |
- |
1 |
1 |
1 |
- |
fischertechnik 30402 interface |
8 |
4 |
- |
2 |
- |
- |
- |
6 |
- |
6 |
- |
fischertechnik 16554 extension |
8 |
4 |
- |
- |
- |
- |
- |
6 |
- |
6 |
- |
ELV Wettersensor-Empf�nger |
- |
- |
- |
1 |
- |
- |
- |
- |
- |
0,1 |
- |
HygroTec meters ** (see meters) |
- |
- |
- |
1 |
- |
- |
- |
- |
- |
1 |
1 sec. |
Sartorius scales |
- |
- |
- |
1 |
- |
- |
- |
- |
- |
1 |
1 sec. |
Dostmann meters |
- |
- |
- |
1 |
- |
- |
- |
- |
- |
1 |
1 sec. |
Voltcarft DIGI 35 CPU |
- |
- |
- |
- |
1 |
- |
- |
- |
- |
1 |
1 sec. |
Voltcraft MXG-9810A |
- |
- |
- |
- |
- |
- |
1 |
- |
- |
1 |
- |
MOTECH LPS-300 series |
- |
- |
- |
- |
1 |
- |
- |
- |
- |
1 |
- |
Multimeter * (see meters) |
- |
- |
- |
1 |
- |
- |
- |
- |
1 |
1 |
1 sec. | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| |
External devices on USB
| |
|
|
| |
| |
Channels |
|
Sample rate
| |
|
| | |
|
|
DI |
DO |
PIO |
AD |
DA |
REL |
CNT |
Digital-ProfiLab |
DMM-ProfiLab |
ProfiLab-Expert |
RealView |
Kolter VModul I/O USB |
16 |
16 |
- |
- |
- |
- |
- |
- |
- |
3 |
- |
Kolter VModul A/D USB |
- |
- |
- |
16 |
- |
- |
- |
- |
- |
0,5 |
5 sec. |
Kolter USB Counter mini |
- |
- |
- |
- |
- |
- |
1 |
- |
- |
2 |
- |
Kolter USB DAC mini |
- |
- |
- |
- |
1 |
- |
- |
- |
- |
2 |
- |
Kolter USB I/O mini |
2 |
2 |
- |
- |
- |
- |
- |
- |
- |
10 |
- |
Kolter USB A/D mini |
- |
- |
- |
1 |
- |
- |
- |
- |
- |
10 |
200 ms |
Kolter USB Proto mini |
16 |
16 |
- |
- |
- |
- |
- |
- |
- |
2 |
- |
Kolter USB Proto |
16 |
16 |
- |
- |
- |
- |
- |
- |
- |
2 |
- |
Kolter USB OPTO-4 mini INP |
4 |
- |
- |
- |
- |
- |
- |
- |
- |
10 |
- |
Kolter USB OPTO-4 mini OUT |
- |
4 |
- |
- |
- |
- |
- |
- |
- |
6 |
- |
ModulBus CompuLab USB |
8 |
8 |
- |
3 |
- |
- |
- |
- |
- |
NA |
NA |
ModulBus SERAI 8/12 USB |
- |
- |
15 |
8 |
- |
- |
- |
- |
- |
30 |
20 ms |
LabJack TM U12 |
- |
- |
20 |
8 |
2 |
- |
1 |
- |
- |
8 |
200 ms |
BMC meM-PIO |
- |
- |
24 |
- |
- |
- |
- |
NA |
- |
NA |
- |
BMC meM-ADfo |
4 |
4 |
- |
16 |
1 |
- |
- |
- |
- |
14 |
50 ms |
BMC meM-ADDA |
8 |
8 |
- |
16 |
1 |
- |
- |
- |
- |
14 |
50 ms |
Meilhaus RedLab PMD1008 |
- |
- |
28 |
8 |
2 |
- |
1 |
- |
- |
3 |
500 ms |
HygroSens USB relay card |
- |
8 |
- |
- |
- |
8 |
- |
1 |
1 |
1 |
- |
QUANCOM USBREL8 |
- |
- |
- |
- |
- |
8 |
- |
20 |
20 |
20 |
- |
ELV UIO88 |
8 |
8 |
- |
- |
- |
- |
- |
- |
- |
5 |
- |
ELV UAD 8 |
- |
- |
- |
8 |
- |
- |
- |
- |
- |
7 |
200 ms |
Velleman K8055 |
5 |
8 |
- |
2 |
2 |
- |
- |
- |
- |
12 |
100 ms |
Code Mercenaries IO-Warrior 24 |
- |
- |
16 |
- |
- |
- |
- |
- |
- |
30 |
- |
Code Mercenaries IO-Warrior 40 |
- |
- |
32 |
- |
- |
- |
- |
- |
- |
30 |
- |
Elexol USB I/O module II |
- |
- |
24 |
- |
- |
- |
- |
60 |
- |
60 |
- |
Multimeter USB * (see meters) |
- |
- |
- |
1 |
- |
- |
- |
1 |
1 |
1 |
1 sec. | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| |
Miscellaneous |
|
|
|
| |
| |
Sample rate
| |
|
| |
|
|
Function |
Digital-ProfiLab |
DMM-ProfiLab |
ProfiLab-Expert |
RealView |
Joystick |
3 axes, 4 buttons |
- |
NA |
NA |
- |
RS-232 |
send & receive |
- |
- |
NA |
- |
LPT port |
port access |
SIM |
SIM |
SIM |
- |
COM port |
port access |
SIM |
- |
SIM |
- |
Ports |
port access |
- |
- |
SIM |
- |
LCD displays on LPT |
HD44780 or compatible |
NA |
NA |
NA |
- | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| |
Meters | |
|
|
| |
|
|
Meters |
* Multimeter (COM) |
M
3610 D, M 3640 D, M 3650 D, M 3830, M 3850, M 4650 CR, MS 9150, MS
9160, Protek 506, M 3860 M, M 4660, GDM 703, GDM 705, ME-22, ME-32, VC
350, VC 608, VC 630, VC 650, VC 670, MXD 4660A, M 3850 M, ME-42, VC
635, VC 655, VC 675, GDM 704, VC 820, VC 840, DMM750 (=Wens700), MAS
345, DT4000ZC, DVM 345 DI, UT60E
|
* Multimeter (USB) |
M-3890D USB |
** HygroTec meters |
Manometer
82xxx, Anemometer 89xx, Thermometer 88xx, Schallpegel 89xx, Hygrometer
87xx, 16-Kanal-Temperatursystem, Hygro-Thermometer
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| |
Remarks
As
RealView is a data acquisition software, it uses only the input
channels of supported devices. Output control is not available with
RealView. ProfiLab supports usage of input channels and output channels
as well. Specialised functions like interrupt control, software upload,
firmware-upload, or special driver functions are usually not supported.
As hardware support changes regularly, it is recommended installing the
latest update for your software from time to time. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|